| HS Code | 418244 |
| Iupac Name | (3R,4S,5R,6R)-3,4,5-tris(trimethylsilyloxy)-6-(trimethylsilyloxymethyl)oxan-2-one |
| Molecular Formula | C20H44O7Si4 |
| Molecular Weight | 520.99 g/mol |
| Cas Number | 98389-25-8 |
| Appearance | Colorless to pale yellow oil |
| Smiles | C[Si](C)(C)O[C@@H]1O[C@@H](CO[Si](C)(C)C)C([C@H]([C@H]1O[Si](C)(C)C)O[Si](C)(C)C)=O |
| Inchi | InChI=1S/C20H44O7Si4/c1-29(2,3)24-13-11-14(25-30(4,5)6)18(21)19(15(12-13)26-31(7,8)9)27-32(10,22)23/h13-15H,11-12H2,1-10H3/t13-,14+,15+,19-/m1/s1 |
| Melting Point | N/A (typically oil at room temperature) |
| Solubility | Soluble in organic solvents (e.g., dichloromethane, chloroform) |
| Storage Conditions | Store under anhydrous conditions, protected from moisture |
| Refractive Index | Approximately 1.427 (literature value) |
| Boiling Point | N/A (decomposes before boiling) |
| Density | Approximately 1.04 g/cm³ (calculated) |
As an accredited (3R,4S,5R,6R)-3,4,5-tris(trimethylsilyloxy)-6-(trimethylsilyloxymethyl)oxan-2-one factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | The chemical is supplied in a 1-gram amber glass bottle, sealed with a PTFE-lined cap, and labeled with safety information. |
| Container Loading (20′ FCL) | Container Loading (20′ FCL): Loaded 3,4,5,6-tris(trimethylsilyloxy) compound in sealed drums, 20-foot container, compliant with chemical transport regulations. |
| Shipping | This product, (3R,4S,5R,6R)-3,4,5-tris(trimethylsilyloxy)-6-(trimethylsilyloxymethyl)oxan-2-one, ships in a sealed, inert atmosphere to prevent moisture or air exposure. It is packed in suitable chemical-resistant containers, with cold packs if required, and compliant with all regulations for sensitive organic reagents. Expedited shipping is recommended. |
| Storage | Store **(3R,4S,5R,6R)-3,4,5-tris(trimethylsilyloxy)-6-(trimethylsilyloxymethyl)oxan-2-one** under an inert atmosphere (e.g., nitrogen or argon) in a tightly sealed container, protected from moisture and air. Keep at 2–8 °C (refrigerator), away from light and incompatible substances such as acids or oxidizing agents. This prevents hydrolysis and degradation of sensitive trimethylsilyl groups. |
| Shelf Life | Shelf life: Stable for up to 1 year when stored dry, in airtight containers, and protected from light at 2–8°C. |
As a specialized manufacturer, we supply (3R,4S,5R,6R)-3,4,5-tris(trimethylsilyloxy)-6-(trimethylsilyloxymethyl)oxan-2-one for use in demanding synthesis workflows within regulated industries. Below, we outline its established downstream applications, relevant standards, integration in customer formulations, and typical output products.
This chiral protected carbohydrate serves as a key building block in multi-step API synthesis, especially in nucleoside-based and glycosylated drug compounds. Its multiple trimethylsilyl groups facilitate selective deprotection and high-yield glycosylation, used under stringent GMP environments to ensure traceability and reproducibility in scale-up. Commonly, this intermediate integrates into protected oligosaccharide or nucleoside precursor routes before final hydrolysis and purification, directly impacting purity profiles and regulatory submission batches.
Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
The protected lactone structure enables site-specific conversion and extension in the synthesis of carbohydrate conjugates, such as glycoprotein mimetics and antibody-drug conjugates. Manufacturers integrate this intermediate into controlled cascade reactions, ensuring proper linkage stability. It supports the precise creation of glycosidic bonds, vital for therapeutic conjugate uniformity and downstream biologics regulatory filings.
Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
Biomedical device fabricators utilize this silyl-protected sugar in the controlled synthesis of glycopolymers, which are used as antifouling coatings and cell-interactive layers. Its reactivity maintains backbone stereochemistry in radical or anionic polymerizations, then allows for post-polymerization deprotection to achieve bioactive surfaces. Each batch undergoes rigorous endpoint testing to match device regulatory filings.
Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
Analytical chemistry producers employ this compound in the synthesis of stable-isotope labeled standards and reference materials, where protected sugars are needed as starting materials for further modification. The robust silyl protection ensures high-purity intermediate isolation, critical for QC programs in pharmaceutical and biochemical laboratories. Each production run supports certification traceable to ISO/IEC 17025 and GLP requirements.
Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
Competitive (3R,4S,5R,6R)-3,4,5-tris(trimethylsilyloxy)-6-(trimethylsilyloxymethyl)oxan-2-one prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
In this industry, experience teaches every day. In the chemical manufacturing world, a name as complex as (3R,4S,5R,6R)-3,4,5-tris(trimethylsilyloxy)-6-(trimethylsilyloxymethyl)oxan-2-one signals that every step in production, every choice in raw materials, and every test for purity leaves a tangible mark on the finished product. Here, we handle nuanced reagents that demand precision and deep chemical understanding, qualities built from years of navigating the intricate steps that fine organic synthesis commands.
Among the many protected sugar derivatives circulating in this sector, this compound occupies a place reserved for those requiring carefully tailored reactivity and solubility characteristics. On our manufacturing floor, clarity matters more than broad claims. This molecule differs from other silylated sugars, such as shorter or bulkier silyl-protected analogs, by the distinct combination of its four trimethylsilyl groups. Each substitution directly influences which transformations chemists pursue next. Batch after batch, we observe this pattern: maintaining the full set of four silyl groups, including at the 6-position as a silyloxymethyl, brings tangible stability and consistent performance for moisture-sensitive transformations. The formation of the lactone ring adds to this, locking the sugar-derived core in a rigid profile that handles with less concern for ring opening and side isomerization, which sometimes undermine related structures. We do not simply list these structural points; our hands and eyes confirm them, day in and day out, through the outcomes of real reactions.
Unlike some peracetylated or dibenzyl-protected analogs, which frequently display issues with migration of protecting groups or incomplete reactions in transition metal-catalyzed steps, the trimethylsilyl system applied here delivers clean cleavage profiles. Removing those protecting groups in the presence of fluoride sources or under mild acidic conditions has given our customers and ourselves reductions in by-product formation, observable both in research synthesis and on scale-up. In a field where overlooked side-products can set back weeks of work, or even risk entire campaigns, these differences possess real business value.
Making this oxanone involves far more than mixing reagents and waiting for the outcome. Every run requires critical inspection of incoming starting materials for trace water. Even minuscule traces lead to hydrolysis of the sensitive intermediates or partial desilylation in later steps. We often see variations in trimethylsilyl chloride batches from upstream suppliers, so water content in both the reagents and the solvents needs real vigilance. Our teams inspect glassware, monitor drying agents, and track temperature cycles with rigour carved from years spent troubleshooting silyl chemistry. That reduces lost product and increases reliability.
Colleagues from research and process development will recognize how processes for introducing the trimethylsilyl groups demand patience and careful purification. Chromatography on silica often strips TMS groups, forcing us to implement alternative purification strategies, such as carefully selected neutral alumina columns or pressurized liquid extraction. These are not tricks lifted from textbooks; they derive from lessons earned in repeated batch runs. Each modification and improvement becomes a line in our playbook, and none escapes scrutiny from our analytic teams. NMR, GC-MS, and QTOF-LCMS data give us confidence in achieving the correct substitution pattern and ring integrity. No batch leaves the plant without this level of inspection.
Inventory management challenges abound in specialty chemicals, but for sensitive molecules like this oxanone, every hour in storage above ambient—every minute exposed to uncontrolled humidity—risks partial degradation. Material handling protocols across our sites call for dedicated storage, use of dry nitrogen or argon blanketing, and custom-sealed containers. These actions keep the active content high and the downstream chemistry reproducible.
Having manufactured silylated compounds from the small scale for preclinical testing to kilogram ranges for scale-up, we see first-hand that even small structural differences show up later. A structure that looks similar at a glance—a tri-silylated oxane, for example, but without the silyloxymethyl arm at the 6-position—often fails to deliver equivalent results in regioselective glycosylation or in forming orthogonally-protected oligosaccharides. Users often return to us to point out lower yields or more by-products, and comparing side by side, our well-defined, fully silylated oxan-2-one delivers higher reproducibility. We attribute this to the combination of silyl protection across the molecule and the stability conferred by the lactone ring. Such features keep this compound in demand for assembly of complex carbohydrates and for use in protecting group strategies during pharmaceutical intermediate synthesis.
Unlike competitors who may outsource or trade intermediate compounds of uncertain provenance, we track every input and analytic checkpoint. The outcomes have borne fruit: our products consistently earn repeat orders from process chemists who verify purity both in-house and with external labs. No batch leaves our facility without meeting tight NMR and MS-based confirmation of the intended pattern—not simply total silyl content, but the right arrangement at every chiral center and through every group. We recognize not all labs hold themselves to these standards. We do, because it directly dictates downstream yield and fidelity.
Our product supports method development in carbohydrate chemistry, oligosaccharide synthesis, and medicinal chemistry. Chemists refining enzyme inhibitors or vaccine building blocks have highlighted the speed and cleanness of silyl group removal, compared to acetyl, benzyl, or benzoyl systems. As manufacturers, we frequently hear from development teams that TMS-protected intermediates offer distinct flexibility for stepwise deprotection sequences, especially crucial when a project’s goal depends on exposing one reactive site at a time. Our material’s predictable response to fluoride or acid deprotection methods has saved time during scale-up, where every unnecessary by-product adds cost.
Some larger pharma projects have leveraged this compound as a core intermediate in glycosyl donor synthesis. From direct conversations with external partners conducting GMP campaigns, we learned how each impurity—such as partially desilylated contaminants—can cause incomplete glycosylation or off-target substitution. Providing high-purity, fully silylated oxan-2-one keeps those projects on schedule. We’ve participated in tech transfer visits and seen the impact first-hand: cleaner product arrives, timeline headaches decrease, teams turn to focus on yield optimization rather than troubleshooting raw material issues.
Differences in protection group strategy may look small from the outside, but process teams know that an extra deprotection step—or a missed functional group protection—translates into extra work, yield loss, and more paperwork. By supplying this precise structure, we directly support the fast, selective chemistry that modern glycoscience demands. During the rare supply crunches, some customers tried switching to alternate protected sugars, only to return to our oxan-2-one when competing syntheses consistently failed to match the desired yield and selectivity.
Producing chemically delicate intermediates continuously reminds us of silyl chemistry’s challenges. Trimethylsilyl groups grant selectivity and compatibility with fluoride deprotection, but their moisture sensitivity makes both scale-up and storage a demanding process. Over the years, we’ve developed better sealed reactor systems, refined inert transfer protocols, and shortened packing-to-shipment lead times so that active product gets to clients before degradation can start. Installing online moisture sensors across reaction trains provides real data for every run, minimizing risks posed by invisible water contamination. By investing in these facilities, we reduce both product wastage and customer downtime.
Dichloromethane, tetrahydrofuran, and other commonly used batch solvents demand careful management, not just for their compatibility with the chemistry but for consistent process safety. MSDS compliance, waste disposal, and spill prevention receive as much attention as the chemistry itself. Our manufacturing teams handle these specifics, confident that these upstream habits pay off in safety and batch uniformity on the back end. Without deep engagement in the shop-floor realities, such precautions might seem exaggerated. For us, they’re just part of daily work.
Countless customers tell us: switching to per-O-trimethylsilylated sugars often results in faster deprotection and less by-product formation than peracetates. Yet, compromised batches from uncertain sources or with incomplete silylation consistently generate issues: reduced reactivity, unexpected NMR shifts, and sticky purification. In many labs, these issues can stall projects, especially where time matters. By running our own analytics and confirming stereochemistry and protection, we help chemists focus on value-adding chemistry instead of resynthesizing starting materials.
Customers also flag stability improvements when using our product compared with methyl ether-protected or triacetylated oxanones. Over many cycles, we have fine-tuned packaging protocols based on this direct feedback, double-sealing shipments for long-haul exports, and designing packaging media that resist chipping or moisture ingress. Every lesson from previous shipments pays off in future wins—not just for us, but for every client on the receiving end who depends on the promised shelf life.
We stay in continuous dialogue with end-users, who describe how focused purification following silyl deprotection shortens their downstream campaigns. In glycosylation cascades, the difference often comes down to side reaction suppression and minimal handling, both of which our compound supports by arriving with high purity and minimal need for pre-cleanup. In real-world manufacturing, these steps translate to lower cost of goods and more robust scale-up.
Margins in this sector hinge on control over small details. Producing (3R,4S,5R,6R)-3,4,5-tris(trimethylsilyloxy)-6-(trimethylsilyloxymethyl)oxan-2-one to high standards turns more on these details than on any macro consideration of “market fit” or “competitive pricing.” Every day in our plant, we track humidity, monitor air quality, enforce strict batch release criteria, and maintain a direct feedback loop to the floor. Only by closing this loop do we ensure that customers benefit from predictable outcomes, not just the “same” name on the invoice.
Our analytic teams keep records stretching back years, cross-verifying each batch with both internal standards and external third-party results. This diligence, accumulated over hundreds of runs, builds credibility that not all suppliers can claim. The nuanced differences in NMR, the subtle distinctions in HRMS patterns—these do not slip past our teams. Industry colleagues often observe that well-made silyl-protected sugars can shave weeks from critical syntheses because their downstream steps run as planned. That’s worth more to serious process chemists than any sticker price.
Every challenge in producing this molecule sharpened our processes. We remember difficult years—the occasional batch lost to trace water, the late-night troubleshooting with plant teams, the uncertainties before we installed better moisture controls. Now, continuous improvement of procedures keeps risk low. Each new customer challenge spurs new process refinements: tweaking layer separations, integrating better inline analytic checks, refining alkylating agent additions to prevent incomplete silylation, and rechecking storage thresholds. The changes show up in customer testimonials and in internal audits showing consistent high-purity output.
A compound such as this, seemingly just another entry in the long list of protected sugars, becomes much more in hands-on manufacturing. Its consistent output and predictable deprotection put time back in chemists’ schedules, reduce project risk, keep campaigns on track. We keep investing in facilities, safety systems, and skill development, because this isn’t an off-the-shelf commodity for us—it’s an outcome of many years’ real work, always sharpened by feedback from other working chemists.
Those using this intermediate in their own synthesis, whether assembling oligosaccharides or working on new therapeutic agents, find value not simply in having “the right name” on the bottle, but in everything underneath—clarity, insight, commitment to detail. This is not the only protected sugar out there. Yet, from raw material checks to controlled packaging, from hand-tracked NMR to the final seal before shipping, we stand behind each batch. We learned this industry’s lessons not from catalogs, but from the real, daily grind of scaling sensitive chemistries. As markets move, as chemists ask more from their starting materials, we aim to meet them steadily, product by well-made product.